Aluzinc HEPA FFU for Cleanrooms

81 Views
Aluzinc HEPA FFU for pharmaceutical cleanrooms: 85–99.999% filtration at 0.3μm, self-contained fan, uniform laminar airflow, no ductwork.
Product Type:
HEPA Fan Filter Unit (FFU)
Housing Material:
Aluzinc (Al-Zn coated steel)
Filtration Efficiency:
85%–99.999% at 0.3 μm
Filter Class:
HEPA H13–H14 / ULPA U15 available
Airflow Pattern:
Uniform laminar (unidirectional) airflow
Fan Type:
Self-contained integrated centrifugal fan
Privacy Policy: Samples are free within a certain price range

Product descriptions

High-Efficiency HEPA Fan Filter Unit for Pharmaceutical Cleanrooms — Aluzinc FFU with 85%–99.999% Filtration @ 0.3μm

This HEPA Fan Filter Unit (FFU) is engineered for pharmaceutical cleanrooms, hospital isolation rooms, and precision manufacturing environments where particulate control is non-negotiable. The integrated aluzinc housing combines a corrosion-resistant zinc-aluminum alloy coating with a self-contained motorized fan module, delivering uniform laminar airflow without external ductwork. With filtration efficiency ranging from 85% to 99.999% at 0.3μm, it adapts to ISO Class 5–8 requirements across a single compact form factor. The 22.6 × 22.6 × 9.6 inch (57.5 × 57.5 × 24.5 cm) footprint fits standard T-bar ceiling grids, enabling drop-in installation and simplified maintenance access.

  • Aluzinc construction: Zinc-aluminum coated steel housing resists corrosion in humid, chemically active cleanroom environments — extending service life versus painted steel alternatives.
  • Wide efficiency band: Selectable 85% to 99.999% @ 0.3μm performance covers HEPA H13–H14 grades, allowing one platform to serve multiple cleanroom classifications.
  • Integrated fan module: Self-contained motor and impeller deliver stable airflow without external duct runs, reducing installation complexity and pressure-drop losses.
  • High dust capacity media: Deep-pleat HEPA filtration extends change-out intervals, lowering total cost of ownership for high-particulate pharmaceutical processes.
  • Compact, grid-compatible size: 22.6 × 22.6 × 9.6 inch dimensions suit standard ceiling grids; custom sizes available for non-standard layouts.
  • Eco-conscious design: Low-energy fan operation and recyclable aluzinc housing support sustainability targets in regulated facilities.

Technical Specifications

Product Type HEPA Fan Filter Unit (FFU)
Filter Media High-efficiency HEPA pleated media
Housing Material Aluzinc (zinc-aluminum coated steel)
Filtration Efficiency 85%–99.999% @ 0.3μm
Particle Rating 0.3μm porosity
Dimensions (L×W×H) 22.6 × 22.6 × 9.6 inch / 57.5 × 57.5 × 24.5 cm
Weight 10 kg (approx.)
Maximum Operating Temperature 176°F (80°C)
Shape Square
Dust Capacity High dust capacity design
Application Air filtration system / cleanroom ceiling
Condition New
Customization Size and color available on request

Application Scenarios

  • Pharmaceutical cleanrooms: ISO Class 5–8 environments for sterile compounding, aseptic filling, and API manufacturing where viable and non-viable particle control is critical.
  • Hospital operating theaters and isolation rooms: Laminar-flow ceilings for infection control and positive/negative pressure zoning.
  • Electronics and semiconductor assembly: Particle-sensitive production areas requiring stable, low-turbulence airflow.
  • Food and beverage processing: Hygiene zones where airborne contamination must be minimized during packaging and handling.
  • Laboratory and research facilities: Clean benches, biosafety cabinets, and controlled-environment enclosures.

For procurement teams comparing filtration platforms, understanding service life and maintenance intervals is essential — see our analysis of HEPA Filter Life: Key Factors Explained to plan replacement cycles accurately. Facilities evaluating pre-filtration stages alongside FFU deployment may also benefit from the data-driven review in The Role of Synthetic Fiber Filter Cotto, which covers upstream dust-removal strategies. For air purifier OEM projects requiring matched HEPA elements, our H13 H14 HEPA Air Purifier Filter Custom range offers complementary custom-size options.

Customization Options

  • Custom dimensions: Non-standard sizes available to match existing ceiling grids, plenum heights, or equipment enclosures.
  • Color selection: Housing finish customized to align with facility color-coding or brand standards.
  • Efficiency grade: Specify target filtration level within the 85%–99.999% @ 0.3μm range to match required cleanroom class.
  • Configuration support: Guidance on fan speed, airflow uniformity, and control integration for multi-unit arrays.

Packaging & Shipping

  • Protective packaging: Each FFU is individually wrapped with edge protection and secured in a reinforced carton to prevent media damage in transit.
  • Palletized consolidation: Multiple units palletized and stretch-wrapped for efficient container loading and reduced handling risk.
  • Flexible logistics: Sea, air, and express freight options available; MOQ from 1 piece supports sample and trial orders.

FAQ

What cleanroom classes can this FFU support?

With efficiency selectable from 85% to 99.999% @ 0.3μm, the unit can be configured for ISO Class 5 through ISO Class 8 environments. The exact class depends on the chosen filter grade, airflow rate, and ceiling coverage ratio — we recommend confirming your target classification before ordering.

Is the fan module included or sold separately?

The fan, motor, and HEPA filter are integrated into a single self-contained unit. This eliminates separate ductwork and simplifies installation into standard T-bar ceiling grids.

Can I order a custom size?

Yes. Custom dimensions and colors are available. Provide your required length, width, height, and target efficiency, and we will confirm feasibility and lead time.

What is the maximum operating temperature?

The unit is rated for continuous operation up to 176°F (80°C), suitable for standard cleanroom and HVAC environments. Applications exceeding this limit require alternative media specifications.

How often should the HEPA filter be replaced?

Replacement intervals depend on particulate load, pre-filtration quality, and operating hours. In pharmaceutical cleanrooms, periodic differential pressure monitoring and particle counting typically govern change-out schedules. Refer to our Can You Clean Medium-Efficiency Air Filt guidance for upstream filter maintenance practices that extend HEPA service life.

Contact Us

Send Inquiry