5 Inch Hydrophobic PTFE Pleated Filter Cartridge 0.22 Micron 222 End Cap
Product descriptions
5 Inch Hydrophobic PTFE Pleated Filter Cartridge — 0.22 Micron Absolute Filtration with 222 End Cap
This 5 inch hydrophobic PTFE pleated filter cartridge delivers 0.22 micron absolute-rated retention for critical liquid and gas filtration where water breakthrough and particle shedding cannot be tolerated. The hydrophobic PTFE membrane repels aqueous liquids while allowing gases and solvents to pass at high flow rates, making it ideal for sterile venting, compressed air, and aggressive chemical service. Built with a standard 222 end cap configuration, it drops directly into existing sanitary filter housings without modification. Each cartridge is individually tested and backed by a 6-month warranty, with machinery test reports and outgoing inspection video available for full procurement traceability.
- Hydrophobic PTFE membrane — naturally water-repellent, prevents aqueous wet-out and microbial carryover in gas and vent applications
- 0.22 micron absolute retention — validated for sterile filtration and bioburden control
- High chemical compatibility — resistant to strong acids, bases, solvents, and oxidizing agents
- Pleated construction maximizes effective surface area for low pressure drop and extended service life
- Standard 222 end cap with double O-ring seal for leak-free installation in sanitary housings
- Low extractables and no fiber release — suitable for high-purity processes
Technical Specifications
| Parameter | Specification |
|---|---|
| Product Type | Hydrophobic PTFE Pleated Filter Cartridge |
| Nominal Length | 5 inch |
| Pore Rating | 0.22 micron (absolute) |
| Membrane Material | Hydrophobic PTFE |
| End Cap Configuration | 222 (double O-ring, bayonet-style) |
| Core Components | Filter Cartridge |
| Filtration Direction | Outside-in (standard) |
| Maximum Operating Temperature | Up to 80 °C (application dependent) |
| Maximum Differential Pressure | 4.0 bar at 20 °C |
| Weight | 1 kg (per unit, packaged) |
| Warranty | 6 months |
| Inspection & Test | Video outgoing-inspection provided; machinery test report provided |
Application Scenarios
- Sterile venting of bioreactors, fermentation tanks, and holding vessels
- Compressed air and process gas filtration in pharmaceutical and food-grade lines
- Filtration of aggressive chemicals, solvents, and photoresist in electronics manufacturing
- Final filtration in water treatment and high-purity chemical delivery systems
- Vent filtration for packaging, filling, and aseptic processing equipment
For teams comparing filtration grades across a facility, our guide on HEPA vs MERV: Which Filter Do You Need? clarifies rating differences, while the breakdown of What Is a HEPA Filter and How Does It Work supports selection of high-efficiency air stages. Users evaluating wound-depth versus membrane filtration can also review String-Wound Filter Cartridge Application Technology and Application Fields for complementary pre-filtration options.
Customization Options
- Alternative end cap configurations (226, DOE, flat gasket) on request
- Custom lengths and pleat counts to match specific housing dimensions
- Choice of O-ring material (silicone, EPDM, FKM, PTFE-encapsulated) for chemical compatibility
- Private labeling and custom packaging for OEM and distributor programs
Packaging & Shipping
- Each cartridge sealed in individual PE bag and protected with end-cap guards
- Packed in reinforced cartons with foam cushioning; master carton dimensions and quantities confirmed per order
- Shipping via air or sea freight with export documentation; inspection video and test report supplied before dispatch
FAQ
Q: What does “hydrophobic” mean for this PTFE filter cartridge?
A: The hydrophobic PTFE membrane repels water and aqueous solutions, so it will not wet out in humid gas streams. This keeps flow rates stable and prevents liquid from passing through during sterile venting and compressed air service.
Q: Is the 0.22 micron rating absolute or nominal?
A: It is an absolute rating, meaning the cartridge is designed to retain particles at or above 0.22 micron with high efficiency, which is why it is used for sterile filtration and bioburden reduction.
Q: Can this cartridge be used with aggressive chemicals?
A: Yes. The PTFE membrane and compatible construction resist strong acids, bases, and solvents. Confirm the correct O-ring material for your specific chemistry before ordering.
Q: What is the minimum order quantity and lead time?
A: MOQ is 1 piece, suitable for sample and trial orders. Lead time depends on configuration and quantity; contact us for current schedules and shipping options.
Q: What documentation is provided with each order?
A: Every shipment includes a machinery test report and video outgoing-inspection record. The cartridge carries a 6-month warranty covering manufacturing defects.