Industrial PTFE Filter Cartridge 0.1-50 Micron 10-40 Inch High Pressure
Product descriptions
Industrial PTFE Filter Cartridge — High-Pressure Liquid Filtration from 0.1 to 50 Micron
This industrial PTFE filter cartridge is engineered for demanding liquid filtration where chemical resistance, high pressure tolerance, and precise particle retention are non-negotiable. With a micron rating range of 0.1 to 50 micron, the cartridge covers applications from fine sub-micron polishing to coarse pre-filtration in a single product family. The PTFE (polytetrafluoroethylene) construction delivers broad chemical compatibility and low extractables, making it suitable for aggressive fluids, high-purity processes, and high-temperature service up to 90 °C. Available in 5″, 10″, 20″, 30″, and 40″ lengths with standard 215, 222, 226, and threaded connections, it drops directly into most industrial cartridge filter housings.
- Wide micron range: 0.1 to 50 micron ratings for coarse, fine, and polishing stages
- High pressure capability: rated to 150 psi maximum working pressure for demanding line conditions
- Superior chemical resistance: PTFE media withstands acids, bases, solvents, and oxidizing fluids
- High-purity performance: low extractables and minimal media migration for critical liquid streams
- Multiple lengths and connections: 5″ to 40″ with 215, 222, 226, and thread options for broad housing compatibility
- Consistent retention: stable pore structure maintains filtration efficiency throughout the service life
Technical Specifications
| Product Name | PTFE Filter Cartridge |
| Material | PTFE (Polytetrafluoroethylene) |
| Micron Rating | 0.1 to 50 micron |
| Maximum Pressure | 150 psi |
| Max. Working Temperature | 90 °C |
| Length | 5″, 10″, 20″, 30″, 40″ |
| Outer Diameter (OD) | 69 mm |
| Inner Diameter (ID) | 28 mm |
| Connection Types | 215, 222, 226, thread, etc. |
| Application | Liquid filtration |
| Condition | New |
| Weight | 2 kg (reference, 10″ configuration) |
| Warranty | 1 year |
Application Scenarios
- Chemical processing: filtration of aggressive acids, bases, and solvents where PTFE inertness is essential
- Pharmaceutical and biotech: high-purity liquid streams requiring low extractables and validated retention
- Electronics and semiconductor: ultra-pure water and process chemical filtration at sub-micron ratings
- Food and beverage: compatible filtration of liquid food products and process water
- Industrial water treatment: pre-filtration and polishing in high-pressure RO and wastewater lines
For buyers comparing filtration technologies across process stages, our guide to String-Wound Filter Cartridge Application Technology and Application Fields explains how wound cartridges complement PTFE membranes in multi-stage liquid filtration trains.
Customization Options
- Length and connection: select from 5″, 10″, 20″, 30″, or 40″ bodies with 215, 222, 226, or threaded end configurations
- Micron rating: specify any retention point across the 0.1 to 50 micron range for your process stage
- End-cap and gasket materials: options matched to your chemical compatibility and temperature requirements
- Private labeling and packaging: OEM branding and custom carton configurations for distributor programs
Packaging and Shipping
- Individually sealed cartridges in protective sleeves, packed in reinforced export cartons
- Minimum order quantity: 25 pieces; mixed length and micron configurations accepted
- Standard export documentation and palletized loading for consolidated container shipments
FAQ
What is the difference between this PTFE filter cartridge and a standard wound cartridge?
PTFE cartridges use a chemically inert fluoropolymer media suited to aggressive fluids and high-purity applications, while wound cartridges use cost-effective fiber media for general-duty filtration. If you are evaluating filter media grades for air or liquid side streams, see HEPA vs MERV: Which Filter Do You Need? for a comparison framework.
Can the cartridge handle 150 psi continuously?
Yes. The 150 psi rating is the maximum working pressure of the cartridge construction, and the PTFE media and support layers are selected to maintain integrity at that pressure within the 90 °C temperature limit.
Which micron rating should I choose?
Select 0.1 to 1 micron for fine polishing and sub-micron retention, 5 to 10 micron for general clarification, and 20 to 50 micron for coarse pre-filtration. Many buyers run a staged configuration to extend final filter life.
Are custom lengths and connections available for OEM orders?
Yes. Lengths from 5″ to 40″ and connections including 215, 222, 226, and thread types are available, and custom end-cap and gasket configurations can be quoted against your specification. For buyers also sourcing air-side filtration, our Maßgeschneiderter HEPA H13 H14 Filter für Luftreiniger HVAC-Panel gefalteter HEPA-Filter page covers customized HEPA panel options.
What is the lead time and warranty?
Standard configurations ship from stock or short production runs; custom specifications are quoted with lead time on confirmation. All cartridges carry a 1-year warranty covering manufacturing defects under normal operating conditions.
English
Español
Français
Italiano
Deutsch
日本語
Русский
العربية
Português
Svenska