H14 HEPA Ceiling Mounted Air Purifier FFU Fan Filter Unit 2×4 for Clean Room

62 Views
H14 HEPA ceiling-mounted FFU for clean rooms and labs. 99.99% @0.3um efficiency, 875 CFM, 304 stainless steel, 5-year warranty.
Application:
Industrial, Laboratory
Warranty:
5 year
condition:
New
Extraction Arm Length (maximum):
customized
Extraction Hose Diameter:
customized
Extraction Hose Length:
customized
Privacy Policy: Samples are free within a certain price range

Product descriptions

H14 HEPA Ceiling Mounted Air Purifier FFU – 2×4 Fan Filter Unit for Clean Room Applications

This H14 HEPA FFU (Fan Filter Unit) is a ceiling-mounted air purification solution engineered for ISO Class 5–8 clean rooms, laboratories, and industrial controlled environments. Delivering up to 875 CFM through a high-efficiency H14 HEPA filter rated at 99.99% @ 0.3µm, it provides consistent laminar airflow and particle-free conditions directly above critical work zones. The 2×4 ft (1175 × 575 mm) form factor integrates seamlessly into standard T-bar and cleanroom ceiling grids, making it ideal for both new installations and retrofit projects. As a dedicated clean room fan filter unit, it combines a low-noise centrifugal fan, uniform airflow distribution, and a robust housing in one compact module.

  • H14 HEPA Filtration: 99.99% efficiency at 0.3µm for particle-sensitive processes
  • High Airflow: Up to 875 CFM ensures rapid air exchange and stable positive pressure
  • Low Noise Operation: Just 48 dB(A) — suitable for laboratories and precision workspaces
  • Durable Construction: Available in SUS304/201 stainless steel or galvanized sheet housing
  • Flexible Voltage: Supports 220V / 380V and customized voltage configurations
  • Certified Quality: CE and ISO certified, backed by a 5-year warranty

Technical Specifications

Product Name H14 HEPA Ceiling Mounted Air Purifier FFU
Filter Type H13 / H14 HEPA Filter
Filtration Efficiency 99.99% @ 0.3µm (H14)
Maximum Air Flow 875 CFM
Standard Sizes 2×4 ft / 4×2 ft; 1175×575 / 1175×1175 / 575×575 mm
Housing Material SUS304 / SUS201 Stainless Steel, Galvanized Sheet
Voltage 220V / 380V (Customized Voltage Available)
Noise Level 48 dB(A)
Weight 50 kg
Mobility Mobile / Ceiling Mounted
Application Industrial, Laboratory, Clean Room
Certification CE, ISO
Warranty 5 Years
Condition New

Application Scenarios

  • Pharmaceutical and biotechnology clean rooms requiring strict particulate control
  • Semiconductor, electronics, and optical assembly environments
  • Hospital operating theaters, isolation rooms, and sterile processing areas
  • Laboratory workstations, fume hoods, and laminar flow benches
  • Food processing and cosmetic production lines with hygiene requirements

Customization Options

  • Filter grade selection: H13 or H14 HEPA based on your cleanliness class
  • Housing material: SUS304, SUS201 stainless steel, or galvanized zinc sheet
  • Voltage configuration: 220V, 380V, or custom voltage to match local power supply
  • Extraction arm length, hose diameter, and hose length tailored to your layout

Packaging & Shipping

  • Each unit is individually wrapped in protective film and packed in a reinforced wooden crate
  • Foam padding and corner guards prevent transit damage to the HEPA filter and housing
  • Shipping via sea, air, or express — wooden packaging complies with ISPM 15 export standards

Frequently Asked Questions

Q1: What is the difference between H13 and H14 HEPA filters in this FFU?

H13 filters capture 99.95% of particles at 0.3µm, while H14 filters achieve 99.99%. For ISO Class 5 or higher clean rooms, H14 is recommended. You can review detailed guidance in our article on HEPA Filter Life: Key Factors Explained to plan replacement cycles effectively.

Q2: Can this ceiling mounted air purifier be used as a standalone unit?

Yes. The FFU is a self-contained module with an integrated fan, making it suitable for standalone ceiling installation or as part of a larger clean room air filtration system. For projects involving multi-stage filtration, understanding media selection is essential — see our technical guide on Gas-Solid and Liquid-Solid Separation: M.

Q3: What is the lead time and MOQ?

MOQ is 1 set. Standard lead time is 7–15 working days depending on configuration and quantity. Customized voltage or material options may extend production time slightly.

Q4: How often should the HEPA filter be replaced?

Under normal clean room conditions, an H14 HEPA filter typically lasts 12–24 months. Replacement frequency depends on ambient particle load, pre-filtration efficiency, and operating hours. Referring to our guide on Common Filter Media Materials and Applic can help you choose compatible pre-filters to extend HEPA life.

Q5: Is technical support or installation guidance provided?

Yes. We provide installation manuals, wiring diagrams, and remote technical support. For large-scale clean room projects, our engineering team can assist with layout planning and airflow calculations.