H13 H14 HEPA Filter 24×24 24×48 M Pleat Box for Laboratory Laminar Air Flow

23 Views
High-efficiency H13/H14 HEPA filter with aluminum alloy frame, fiberglass media, and hot-melt separator. Ideal for laboratory laminar air flow. Customizable sizes, ISO9001 certified, 1.5-year warranty.
warranty:
1.5 year
weight:
kg
condition:
New
dimension(l*w*h):
Customizable
efficiency:
H13 H14
porosity:
No
Privacy Policy: Samples are free within a certain price range

Product descriptions

H13/H14 HEPA Filter 24×24 & 24×48 M-Pleat Box for Laboratory Laminar Air Flow

This M-Pleat Box HEPA filter is engineered for critical cleanroom and laboratory laminar air flow applications where particle control cannot be compromised. Available in H13 and H14 efficiency grades, it delivers 99.95%–99.995% filtration at the most penetrating particle size (MPPS) of 0.3 micron, using high-grade fiberglass media and hot-melt separators. The aluminum alloy frame and gel-glue sealant ensure structural rigidity and zero air bypass under continuous duty. Supplied in standard 24×24 and 24×48 inch face dimensions with customizable depth, it is a direct-fit replacement for most horizontal and vertical laminar flow benches and FFUs.

  • H13/H14 dual-grade efficiency for ISO Class 5–8 cleanroom compliance
  • High-density fiberglass media with hot-melt separators for low pressure drop and uniform airflow
  • Aluminum alloy frame with gel-glue sealing — no leakage, no media migration
  • M-Pleat box construction maximizes media area within compact 24×24 / 24×48 footprints
  • Temperature resistance up to ≤100 °C for demanding laboratory environments
  • ISO9001 certified manufacturing with machinery test report and outgoing inspection video provided

Technical Specifications

Parameter Specification
Type M-Pleat Box HEPA Filter
Efficiency Grade H13 / H14
Filtration Precision 0.3 micron (MPPS)
Media Material Fiberglass
Frame Material Aluminum alloy
Separator Hot-melt
Sealant Gel-glue
Standard Face Dimensions 24×24 in / 24×48 in (610×610 mm / 610×1220 mm)
Dimension (L*W*H) Customizable
Temperature Resistance ≤100 °C
Condition New
Warranty 1.5 years (core components included)
Certification ISO9001
Application Laminar Air Flow / Cleanroom FFU

Application Scenarios

  • Laboratory laminar flow hoods and biosafety cabinets requiring H13/H14 particulate control
  • Pharmaceutical and food & beverage production areas with strict microbial and particle limits
  • Electronics, semiconductor, and printing shops where airborne contamination affects yield
  • Hospital cleanrooms, compounding pharmacies, and building material testing labs
  • Energy & mining and construction worksite clean zones with portable filtration units

For facilities running multiple filtration stages, pairing this terminal HEPA stage with pre-filtration upstream extends service life — see our guide on when filter media should be replaced to build an effective change-out schedule. Where liquid or hydraulic circuits are also part of the process, the String-Wound Filter Cartridge Application Technology and Application Fields reference covers complementary depth-filtration selection.

Customization Options

  • Custom face dimensions and depths to match existing laminar flow housings and FFU slots
  • Choice of H13 or H14 efficiency grade per zone classification requirement
  • Optional gasket profiles and sealant configurations for specific frame interfaces
  • Private labeling and OEM packaging for distributors and cleanroom integrators

Packaging & Shipping

  • Each filter is individually wrapped and corner-protected, then packed in reinforced export cartons
  • Palletized loading with moisture barrier and shock-absorbing layers for long-haul sea freight
  • Machinery test report and outgoing-inspection video supplied with every shipment; online and video technical support available after delivery

FAQ

Q: What is the difference between H13 and H14 in this filter?

H13 provides ≥99.95% efficiency at 0.3 micron, while H14 provides ≥99.995%. Both use the same fiberglass media and aluminum frame construction; the grade is selected according to your cleanroom class and local regulatory requirements.

Q: Can the 24×24 and 24×48 sizes be customized?

Yes. The M-Pleat Box design is fully customizable in length, width, and depth. Provide your existing housing or FFU dimensions and we will match the filter to your interface, including gasket and sealant details.

Q: What is the recommended replacement interval?

Replacement depends on upstream pre-filtration and load. In typical laboratory laminar flow service, 12–24 months is common; monitor pressure drop and replace when it reaches 1.5–2× the initial resistance. Our article on Oil Filters vs. Fuel Filters explains analogous differential-pressure logic for fluid systems, which helps maintenance teams standardize change-out criteria across equipment types.

Q: Is technical support available after purchase?

Yes. We provide online support and video technical guidance for installation, sealing verification, and troubleshooting throughout the 1.5-year warranty period covering core components.

Q: What certifications and documentation are included?

The product is manufactured under ISO9001. A machinery test report and video outgoing inspection are provided with each order; additional documentation can be arranged for project tenders.

Contact Us

Send Inquiry

Frequently bought together

Close Inquiry Basket

Send Inquiry
Close

Send Inquiry
Close
Chat with us! Search products Inquiry Basket Back to top
Close Inquiry Basket

Send Inquiry

Send Inquiry