Plastic Frame V-Bank Compact HEPA Air Filter F6-F9 H10-H12 for AHU HVAC High Airflow Low Pressure Drop
Product descriptions
Plastic Frame V-Bank Compact HEPA Air Filter — F6–F9 / H10–H12 for AHU & HVAC Systems
The Plastic Frame V-Bank Compact HEPA Air Filter is engineered for high-airflow AHU and HVAC installations where both filtration efficiency and energy consumption matter. Its rigid V/W-type pleated structure packs a large filtration surface into a compact 292 mm depth, delivering 99.9% efficiency at 0.3 µm while keeping pressure drop low. Available in F6–F9 and H10–H12 grades, this compact HEPA filter is a direct drop-in solution for commercial buildings, cleanrooms, and industrial process air. For a deeper engineering perspective on how V-bank geometry balances media area against resistance, see V-Bank Panel Filters: A Technical Deep D.
- High airflow, low pressure drop: The V-bank configuration maximizes effective media area, reducing fan energy demand while maintaining rated efficiency.
- Compact footprint: Standard 592×592×292 mm size fits most AHU filter racks without structural modification.
- Dual frame options: Lightweight ABS/PVC plastic frame or reinforced aluminum frame for high-temperature and heavy-duty duty cycles.
- Broad efficiency range: Filtration grade from 95% to 99.999%, covering F6–F9 pre-filtration and H10–H12 HEPA-class final filtration.
- Stable pleat geometry: Hot-melt bead separators and rigid frame prevent pleat collapse under turbulent airflow.
- Outgoing inspection provided: Every batch is video-inspected before shipment for pleat integrity, seal, and dimensional accuracy.
Technical Specifications
| Product Name | W-Type / V-Bank Compact HEPA Air Filter |
| Type | W-Type High Efficiency Filter |
| Structure | V / W Type (mini-pleat) |
| Filtration Grade | F6–F9 (95%–99.9%) / H10–H12 (99.9%–99.999%) |
| Efficiency | 99.9% @ 0.3 µm |
| Porosity / Particle Rating | 0.3 µm |
| Frame Material | Aluminum frame or ABS / PVC plastic frame |
| Standard Dimension (L×W×H) | 592 × 592 × 292 mm |
| Custom Dimensions | Available on request |
| Number of Sections | Standard configuration |
| Drain Type | Standard |
| Weight | Approx. 3 kg |
| Condition | New |
| Feature | Large Air Flow, Low Pressure Drop |
| Warranty | Not available |
| Video Outgoing Inspection | Provided |
Application Scenarios
- Commercial HVAC & AHU systems: Final-stage filtration in air handling units for hotels, offices, and shopping centers.
- Manufacturing plants: Process air protection for electronics, pharmaceutical, and precision machinery assembly areas.
- Machinery repair shops: Dust and particulate control in paint booths and workshop ventilation.
- Cleanroom pre-filtration: H10–H12 grades serve as upstream protection for H13/H14 terminal filters — pair with our H13 H14 Box HEPA Filter 99.999% Efficien for a complete filtration train.
- Industrial dust recovery: Suitable for gas-solid separation duties where media selection affects service life; see Gas-Solid and Liquid-Solid Separation: M for media guidance.
Customization Options
- Dimensions: Non-standard L×W×H sizes manufactured to your AHU rack drawings.
- Frame material: Choose ABS/PVC plastic frame for lightweight handling or aluminum frame for higher mechanical strength.
- Efficiency grade: Specify F6, F7, F8, F9, H10, H11, or H12 media to match your pressure-drop and cleanliness targets.
- Gasket & seal: Optional gasket profiles for leak-free mounting in critical installations.
Packaging & Shipping
- Individually wrapped in protective film, then packed in reinforced export cartons to prevent pleat deformation in transit.
- Carton quantities sized for palletized LCL and FCL shipments; custom pallet labeling available.
- Outgoing video inspection recorded before dispatch; shipping documents and traceability data supplied with each order.
FAQ
What is the difference between the F6–F9 and H10–H12 versions?
F6–F9 grades are medium-to-high efficiency filters typically used as pre-filters, while H10–H12 grades meet HEPA-class performance for final filtration. Both share the same V-bank compact construction and 292 mm depth, so they are interchangeable within the same rack.
Can this V-bank HEPA air filter be used in high-humidity environments?
The plastic frame resists moisture better than standard paper frames, making it suitable for many humid AHU applications. However, for consistently saturated airstreams, specify the aluminum frame option and confirm media compatibility with your process conditions.
How often should the filter be replaced?
Replacement intervals depend on upstream dust loading and pre-filtration quality. Monitoring pressure drop is the most reliable indicator — replace when resistance reaches the terminal value specified for your AHU. Factors affecting service life are outlined in HEPA Filter Life: Key Factors Explained.
Do you provide custom sizes for non-standard AHU racks?
Yes. Dimensions are fully customizable. Provide your rack opening dimensions, required airflow, and target efficiency grade, and we will confirm the matching configuration.
Is a sample order possible before bulk purchase?
Yes, the minimum order quantity is 1 piece, allowing single-unit evaluation before committing to volume production.
English
Español
Français
Italiano
Deutsch
日本語
Русский
العربية
Português
Svenska