Industrial Mini-Pleated ULPA/HEPA Air Filter for Biosafety Cabinet – 99.99% Efficiency
Product descriptions
Industrial Mini-Pleated ULPA/HEPA Air Filter for Biosafety Cabinets — 99.99% Efficiency at 0.3 µm
This mini-pleated HEPA air filter is engineered for biosafety cabinets, laminar flow hoods, and other critical cleanroom applications where particle control is non-negotiable. Built with American HV micron glass fiber media and a hot-melt bead separator, it delivers 99.99% efficiency at 0.3 µm and scales up to 99.999995% at 0.12 µm for ULPA-grade configurations. The rigid frame — available in aluminum, galvanized steel, stainless steel, or plastic — maintains pleat geometry under continuous airflow, while the PU polyurethane sealant and endless gasket ensure a leak-free seal at the cabinet interface. Each unit is a new-condition, direct-fit replacement designed for OEM and MRO procurement programs with a 20-piece minimum order.
- Dual-grade filtration in one platform: HEPA (99.99% @ 0.3 µm) and ULPA (up to 99.999995% @ 0.12 µm) configurations from a single mini-pleated design
- High-density pleat pack: Hot-melt bead separators maximize media surface area, lowering pressure drop and extending service life
- American HV micron glass fiber media: Consistent fiber diameter and basis weight for repeatable efficiency across production lots
- Leak-tight construction: PU polyurethane sealant bonds media to frame; endless gasket (EVA or Neoprene) eliminates bypass at the housing seal
- Four frame options: Aluminum, galvanized steel, stainless steel, or plastic to match cabinet spec and budget
- Harsh-environment ready: Rated to 70 °C maximum temperature and 100% maximum humidity
Technical Specifications
| Filter Type | HEPA / ULPA mini-pleated filter |
| Media | American HV micron glass fiber |
| Efficiency | 99.99% @ 0.3 µm ~ 99.999995% @ 0.12 µm |
| Porosity / Particle Rating | 0.3 µm |
| Frame Material | Aluminum / galvanized steel / stainless steel / plastic |
| Separator | Hot melt bead |
| Sealant | PU polyurethane |
| Gasket | Endless gasket / EVA / Neoprene |
| Optional Aluminum Depth | 38 mm ~ 150 mm |
| Dimensions (L×W×H) | Standard size (custom on request) |
| Max. Temperature | 70 °C |
| Max. Humidity | 100% |
| Weight | Approx. 2 kg |
| Condition | New |
| Core Component | Filter efficiency (media pack) |
Application Scenarios
- Biosafety cabinets (Class II A2 / B2) and biological safety enclosures
- Laminar flow hoods and clean benches for pharmaceutical and laboratory work
- Cleanroom terminal filtration in electronics, semiconductor, and optical assembly
- Hospital operating rooms, isolation wards, and sterile processing areas
- Pharmaceutical filling lines and aseptic processing equipment
For buyers comparing pleat-pack constructions across grades, our H13 PES Pleated Filter, Aluminum Frame offers a complementary H13 PES option for general cleanroom use. When specifying media for high-moisture or washdown environments, the data in our Comparison of Hydrophobic Performance Between Sintered PTFE and Metal Filters helps validate material selection. Replacement interval planning is covered in When Should Filter Media Be Replaced?, and buyers evaluating upstream fluid filtration can reference Oil Filters vs. Fuel Filters for cross-category context.
Customization Options
- Frame material: aluminum, galvanized steel, stainless steel, or plastic — selected per cabinet specification
- Frame depth: aluminum depths from 38 mm to 150 mm to match existing housing pockets
- Gasket type: endless gasket, EVA, or Neoprene depending on seal compression and chemical exposure
- Efficiency grade: HEPA 99.99% @ 0.3 µm or ULPA up to 99.999995% @ 0.12 µm
Packaging & Shipping
- Individual PE bag protection with rigid edge guards; master cartons sized to prevent pleat compression in transit
- Minimum order quantity: 20 pieces; mixed frame and gasket configurations accepted within one order
- Export-standard cartoning with palletization on request; shipping marks and labels to buyer specification
FAQ
What is the difference between the HEPA and ULPA versions of this filter?
Both share the same mini-pleated glass fiber platform and frame construction. The HEPA configuration is rated 99.99% at 0.3 µm for standard biosafety cabinet and cleanroom duty; the ULPA configuration extends to 99.999995% at 0.12 µm for applications requiring the highest particle removal, such as semiconductor or high-containment environments.
Can the filter depth be customized to fit our existing cabinet?
Yes. Optional aluminum frame depths range from 38 mm to 150 mm, and overall dimensions are built to standard or customer-specified sizes. Provide your housing pocket dimensions and gasket groove profile when requesting a quotation.
What operating conditions does the filter tolerate?
The filter is rated for a maximum temperature of 70 °C and maximum humidity of 100%, making it suitable for humidified incubator-adjacent cabinets and washdown-accessible cleanroom installations.
How do we determine when to replace the filter?
Replacement is typically driven by pressure drop reaching the cabinet manufacturer’s threshold or by scheduled maintenance intervals. Our guide on When Should Filter Media Be Replaced? outlines the pressure-drop and interval-based criteria used across HEPA and ULPA installations.
What is the minimum order quantity and lead time?
The MOQ is 20 pieces. Lead time depends on frame material, gasket selection, and efficiency grade; confirm configuration details with our sales team for a firm production and shipping schedule.