H13 H14 HEPA Panel Air Filter 0.3 Micron 99.99% Efficiency Fiberglass Aluminum Frame for FFU Cleanroom HVAC
Product descriptions
H13/H14 HEPA Panel Air Filter — 0.3 Micron, 99.99% Efficiency, Fiberglass Media with Aluminum Frame
This HEPA panel air filter is a single-panel, dry-type high-efficiency particulate air filter engineered for FFU modules, cleanroom ceilings, and critical HVAC systems. Built with glass fiber media and a rigid aluminum alloy frame, it delivers 99.99% efficiency at the most penetrating particle size (MPPS) of 0.3 micron, meeting H13 and H14 grade requirements. The standard 915×610×69 mm footprint matches common FFU configurations, while perimeter sealing ensures zero bypass leakage at the frame interface. Designed for industrial buyers who need repeatable filtration performance, low pressure drop, and long service life in continuous-duty environments.
- 99.99% @ 0.3 μm efficiency — H13/H14 grade performance validated for cleanroom and FFU applications
- Glass fiber media — high dust-holding capacity with stable efficiency across the filter’s service life
- Aluminum alloy frame — lightweight, corrosion-resistant, and dimensionally stable under variable airflow
- Perimeter gasket seal — prevents air bypass and protects ISO class ratings at the mounting interface
- Single-panel dry construction — no drainage required, simplified installation and disposal
- Custom dimensions available — manufactured to your FFU or AHU drawing for drop-in replacement
For procurement teams comparing filtration grades across HVAC and cleanroom duties, our technical guide HEPA vs MERV: Which Filter Do You Need? explains where H13/H14 panel filters sit relative to MERV-rated products. If you need background on media behavior and particle capture mechanics, see What Is a HEPA Filter and How Does It Work.
Technical Specifications
| Parameter | Specification |
|---|---|
| Product Type | HEPA Panel Air Filter (single panel) |
| Filter Grade | H13 / H14 |
| Efficiency | 99.99% @ 0.3 micron (MPPS) |
| Filter Media | Glass Fiber |
| Frame Material | Aluminum Alloy |
| Standard Dimension (L×W×H) | 915 × 610 × 69 mm |
| Custom Dimensions | Available to customer drawing |
| Porosity / Particle Rating | 0.1–0.3 micron |
| Gasket Location | Perimeter seal |
| Drain Type | Dry type |
| Air Inlet Size | Standard FFU size |
| Maximum Flow Rate | Per FFU specification |
| Max. Operating Pressure | Per FFU specification |
| Max. Operating Temperature | Per FFU specification |
| Condition | New |
| Warranty | 1 Year |
| Quality Standard | ISO9001 |
Application Scenarios
- FFU (Fan Filter Unit) modules in ISO Class 5–8 cleanrooms
- Pharmaceutical, semiconductor, and electronics manufacturing environments
- Cleanroom ceiling grids and laminar flow hoods
- Critical HVAC terminal filtration in hospitals and laboratories
- Industrial air filtration where 0.3 micron particle control is required
Customization Options
- Custom length, width, and depth to match existing FFU or AHU filter frames
- H13 or H14 grade media selection based on your target ISO class
- Gasket configuration options for specific housing profiles
- Private labeling and OEM packaging for distributor programs
For projects combining panel filters with other cartridge-based filtration stages, our article on String-Wound Filter Cartridge Application Technology and Application Fields covers complementary pre-filtration and process water filtration configurations.
Packaging & Shipping
- Individual protective wrapping with rigid edge protection to prevent media damage in transit
- Carton packaging sized for palletized LCL and FCL shipment; master carton quantities confirmed per order
- Export documentation, including packing list and certificate of conformity, provided with every shipment
FAQ
What is the difference between H13 and H14 efficiency?
Both grades are tested at 0.3 micron. H13 is rated at 99.95% and H14 at 99.99%. This product is available in either grade; specify your target ISO class and we will confirm the appropriate configuration.
Can the filter dimensions be customized for our FFU brand?
Yes. The 915×610×69 mm size is our standard FFU footprint, but we manufacture to customer drawings. Provide your frame dimensions and gasket profile and we will quote a matching panel.
Is the filter suitable for high-temperature HVAC installations?
Maximum operating temperature follows the FFU specification. Share your operating conditions during inquiry so we can confirm media and gasket compatibility before shipment.
What is the minimum order quantity and lead time?
MOQ is 1 piece for sample and trial orders. Production lead time depends on quantity and customization level; standard sizes ship faster than fully custom panels.
How should the filter be stored before installation?
Store in original packaging in a dry, dust-free area, away from direct sunlight and sharp objects. Do not remove the protective wrapping until the filter is ready to be installed in the FFU or housing.