H14 HEPA Air Filter 99.99% Efficiency Aluminum Foil Separator for Laminar Flow Hood

45 Views
High-efficiency H14 HEPA air filter with 99.99% efficiency, aluminum foil separator, and fiberglass media. Ideal for laminar flow hoods and air filtration systems. OEM/ODM available.
Type:
Air Filter Element
warranty:
1 Year
weight:
4
condition:
New
dimension(l*w*h):
610x610x90,610x915x93,610x1220x90,customizied
efficiency:
99.99%
Privacy Policy: Samples are free within a certain price range

Product descriptions

H14 HEPA Air Filter with Aluminum Foil Separator — 99.99% Efficiency for Laminar Flow Hoods

This H14 HEPA air filter is a high-capacity terminal filtration element engineered for laminar flow hoods, clean benches, and critical air filtration systems requiring particle removal efficiency of 99.99% at MPPS. Built with deep-pleated glass fiber media and a corrugated aluminum foil separator, the element maintains uniform pleat spacing and stable airflow even under high pressure drop, preventing media collapse and channeling over the service life. The anodized aluminum alloy frame delivers structural rigidity with low outgassing, making it suitable for ISO Class 5 cleanrooms, pharmaceutical filling lines, and electronics manufacturing environments. Available in standard face dimensions and fully customizable configurations, this H14 HEPA filter is a drop-in replacement for most laminar flow hood and FFU installations.

  • 99.99% filtration efficiency at MPPS (H14 grade per EN 1822), validated for critical cleanroom and laminar flow applications
  • Aluminum foil separator design maintains precise pleat geometry, resists moisture-induced media binding, and extends service life under high-humidity conditions
  • Deep-pleated glass fiber media provides high dust holding capacity with low initial pressure drop for energy-efficient operation
  • Aluminum alloy frame — lightweight, corrosion-resistant, and dimensionally stable, with no outgassing in sensitive environments
  • Eco-friendly construction — media and separator are fully incinerable, reducing disposal costs and environmental impact
  • OEM/ODM available — custom dimensions, frame profiles, and gasket options for volume buyers and private-label programs

Technical Specifications

Parameter Specification
Product Type Air Filter Element — H14 HEPA Air Filter
Filtration Grade H14 (EN 1822)
Efficiency 99.99% @ MPPS
Filter Media Deep-pleated glass fiber + aluminum foil separator
Frame Material Aluminum alloy
Standard Dimensions (L×W×H) 610×610×90 mm / 610×915×93 mm / 610×1220×90 mm
Custom Dimensions Available upon request
Porosity Standard
Weight Approx. 4 kg (varies by size)
Condition New
Warranty 1 Year
Application Air filtration system / laminar flow hood
Usage Home and commercial air purifiers, cleanroom equipment
OEM/ODM Yes

Application Scenarios

  • Laminar flow hoods and clean benches — terminal filtration for ISO Class 5 horizontal and vertical flow workstations
  • Pharmaceutical and biotechnology — aseptic filling zones, biosafety cabinets, and sterile processing areas
  • Electronics and semiconductor manufacturing — particle control in wafer fabrication and assembly environments
  • Commercial air purification systems — high-efficiency final-stage filtration in hospitals, laboratories, and food processing facilities
  • HVAC and FFU retrofits — direct replacement element for existing fan filter units and cleanroom ceiling grids

For facilities managing multiple filtration stages, pairing this H14 terminal filter with pre-filtration elements such as a Custom 0.2-200um SS Sintered Filter Cartridge upstream can significantly extend HEPA service intervals and reduce total cost of ownership.

Customization Options

  • Custom dimensions — non-standard face sizes, depths, and frame profiles manufactured to your drawing or sample
  • Gasket and seal options — neoprene, EPDM, or PU gaskets; knife-edge or gel seal configurations for leak-free installation
  • Private labeling and packaging — OEM/ODM branding, custom carton printing, and pallet configurations for distributor programs
  • Efficiency grade selection — H13 or H14 media options to match your cleanroom classification and budget requirements

Packaging & Shipping

  • Each filter is individually wrapped in protective film and packed in a reinforced export carton with foam corner protection to prevent media damage in transit
  • Standard carton quantities are optimized for container loading; palletized shipments available for large orders with moisture-barrier wrapping
  • Shipping via air freight or sea freight depending on order volume; EXW, FOB, and CIF terms available — contact us for lead times and freight quotations

Frequently Asked Questions

Q: What is the difference between H13 and H14 HEPA filters?

A: H13 filters are rated at 99.95% efficiency at MPPS, while H14 filters achieve 99.99%. This H14 HEPA filter meets the stricter H14 classification, making it suitable for ISO Class 5 cleanrooms and applications where the highest particle removal assurance is required.

Q: Why use an aluminum foil separator instead of hot-melt separators?

A: Aluminum foil separators maintain rigid, uniform pleat spacing under high airflow and pressure drop, preventing media collapse and channeling. They are also moisture-resistant and fully incinerable, which simplifies disposal and supports eco-friendly waste handling compared with some alternative separator materials.

Q: Can this filter be used as a direct replacement in existing laminar flow hoods?

A: Yes. The standard 610×610×90 mm, 610×915×93 mm, and 610×1220×90 mm sizes cover most common laminar flow hood and FFU footprints. For non-standard installations, we manufacture custom dimensions to your drawing — simply provide the frame size, depth, and gasket type required.

Q: How often should the HEPA filter be replaced?

A: Replacement intervals depend on upstream air quality and operating hours. In typical cleanroom service with adequate pre-filtration, H14 elements last 2–5 years. Monitor pressure drop across the filter — when it reaches 1.5–2× the initial value or airflow falls below design specifications, the element should be replaced. For guidance on filtration media lifecycle management, refer to our article on when filter media should be replaced.

Q: Do you offer OEM/ODM services and what is the minimum order quantity?

A: Yes, we support OEM/ODM programs including custom dimensions, branding, and packaging. The minimum order quantity is 1 piece for standard sizes, with volume pricing available for bulk orders. For buyers comparing filtration technologies across applications, our resource on String-Wound Filter Cartridge Application Technology provides useful context on complementary filtration solutions.

Contact Us

Send Inquiry

Frequently bought together

Close Inquiry Basket

Send Inquiry
Close

Send Inquiry
Close
Chat with us! Search products Inquiry Basket Back to top
Close Inquiry Basket

Send Inquiry

Send Inquiry